CHASSIS
- Single axle to carry up to1500kg, brake damped tow hitch
- Spring loaded handbrake
- 12" wheels and tyres
- A-frame welded to chassis
- Tow hitch bolted through A-frame
- Four corner steadies
BODY
- GRP 5 ply board, white high gloss, polished both sides
- All corners supported by polished aluminium angles
- All floor areas are covered with hardwearing fibreglass
- Aluminium around doors and frames
- All doors are self-closing and fitted with an airtight rubber/foam strip
- Yale locks fitted to external doors
- All electrical cables concealed
- Grab handles fitted as standard
- Appropriate warning signs
- Rub rails fitted to outside side walls
INTERNAL SIZES (approximate)
- Clean end 1550 x 1800 mm (at widest points)
- Shower End 1550 x 1000 mm
- Dirty End 1550 x 840 mm
CLEAN END
- Textured fibreglass covered floor and lower walls
- Lockable sealed external door with vent
- Eight personnel lockers
- Mains electric box, light, & 2 x 13A charging sockets
- Mirror and hooks
- Tube heater
- Water drain point
- Self-closing door from shower area
- Waste water pump switch
- Waste pump and filter
SHOWER AREA
- Fibreglass covered floor and lower walls
- Non-slip matting on floor
- Two individually controlled showers
- Water drain point
- Mirrors and hooks
- Self-closing door from dirty end
- Light
- All pipework concealed
- Sink unit
DIRTY END
- Fibreglass covered floor and lower walls
- Removable air extraction unit beneath removable bench
- Mirror and hooks
- Light
- Water drain point
- Self-closing door from exterior
- Tube heater
HEATING AND PLUMBING
- A Pumped waste water filter system
All gas appliances are fitted,
tested and certified by C.I.T.B. assessed engineers and conform to
current Gas Safety Installation and Use Regulations 1994. The gas water
heater must be regularly serviced, according to manufacturers
instructions. The unit also comes with an electrical installation
certificate issued by a registered NICEIC electrician. Installation on
site must be carried out by a competent person along with regular safety
checks of the unit and any portable appliances according to HSE
regulations and/or guidelines.
STANDARD ITEMS FITTED TO THERMAC DECONTAMINATION UNITS
- Pumped waste water filter system
- Plastic plumbing as opposed to usual copper or chrome
- Hand wash basin in clean end (shower compartment
only in the AlleyCat unit)
- Bench seat over NPU
- 15m 240v armoured cable and plug-in RCD
- 15m fresh and waste braided hose
- 2 sets of steps
- Propane gas regulator, isolating valve and test point
- Grab handles fitted to all corners
- 15m fresh and 15m waste water hose pipes
- Leg key
- Road light to current regulations, including front marker lights
- Test certificates for gas water heater and electrical appliances
- DatatagĻ security marking system
EXTRAS AVAILABLE ON THERMAC DECONTAMINATION UNITS
- Hitch Lock (Enclosed Type)
- Wheel Clamp
- Replacement 5 or 20 Micron Water Filter
- Optional 240v Power Points
- Spare Wheel and Tyre
- Fire Extinguisher 1kg Dry Powder
- First Aid Kit
- High Level Side Marker Lights
- Rear Lamp Cluster Guards
- Soap Dispensers